9.3

establishing draft

!
WARNING
Always operate this appliance with the door closed and latched except during start-up and re-fueling.
note:
Remove all sources of gasoline or other fl ammable vapours and liquids in the vicinity of this or other appliances
prior to lighting.
To reduce smoking when starting the appliance, roll up
some newspaper, place it near the appliance fl ue and light
it until chimney begins to draw.
When a fi re has been established and it is necessary to
reload or adjust the fuel, open the doors slowly to avoid
drawing smoke into the room.
A properly installed Napoleon appliance should not smoke.
If yours does, check the following:
Has the chimney had time to get hot?
Are the air intake hoods blocked or closed?
Is the smoke passage blocked anywhere in the appliance or chimney?
Is the smoke fl ow impeded by too long a horizontal pipe or too many bends?
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too short a chimney, or a
chimney too close to trees or a higher roof?