2.0 general information

EN
There are many other appliances in the home competing with this appliance for air, such as kitchen range hoods,
forced air heating devices, and bathroom exhaust fans. Therefore, in order to avoid fi re hazards and/or injuries, be
sure to provide suffi cient combustion air to this appliance.
2.1

general instructions

note:
Do not install an appliance insert or other products/accessories not specifi ed for use with this appliance.
!
WARNING
Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
This appliance must be installed by a qualifi ed installer. Follow the installation directions. Do not operate
without fully assembling all components.
If this appliance is not properly installed, a house fi re may result.
Do not expose the appliance to the elements (ex. rain, etc.) and keep the appliance dry at all times. Wet
insulation will produce an odour when the appliance is used.
This appliance is hot when operated and can cause severe burns if contacted. Children and pets must be
kept from touching the appliance when it is hot. Contact your local authorized dealer/distributor for safety
screens that may be available for this product.
Combustible material such as fi rewood, wet clothing, etc. placed too close can catch fi re. Objects placed
in front of the appliance must be kept a minimum of 48" (121.9cm) from the front of the appliance.
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes and with
the national electric code ANSI/NF No. 70-current (in the United States), or with the current CSA C22.1
Canadian Electric Code (in Canada).
1.
Combustion and dilution air is brought into
the appliance through the fresh air intake col-
lars located on the bottom front sides of the
appliance.
2.
The combustion air is brought into the fi rebox
through many small holes in the airwash
located at the top and sides of the opening.
3.
The dilution air is introduced high in the fi re-
box above the baffl e to cool the chimney.
4.
Inside the fi rebox combustion takes place
and exhausts out the chimney.
5.
The optional blower can be installed to draw
fresh outside air into the home (not recom-
mended in colder climates), then either the
NZ150-KT kit or the NZ64 blower can be
installed inside and will circulate the air into
your home.