Installing the air conditioning system

Place installation template in stowage compartment and fix in
position.
Mark the mounting holes for the 2 brackets (2 – HW) and the
2 side fastening brackets (3).
11
Ø 50 mm
KO
2
1
Fig. 4
Mark floor opening "LE" for the supply air intake, "LA" for the
supply air outlet and "KO" for the condensation drain.
Remove template and cut out the marked floor openings.
Before drilling, always check for underlying / concealed
cables, gas lines, frame sections and the like!
Then seal the edges of the openings in the floor of the vehicle
with underbody protection.
Screw on the 2 side fastening brackets (3) with 2 screws each
and the 2 brackets (2 – HW – leg must be pointing towards
the outside!) with 3 screws each.
Insert connection (11) for condensation drain (KO) from above.
Seal connection (11) for condensation drain all round from
below using body sealant.
3
2
3
LA
LE
5
When installing the unit, please ensure that the
connection (11) of the condensation drain is lo-
cated in the recess in the floor of the vehicle. Otherwise
there is a risk of water penetrating the interior! In order
to provide perfect air circulation the apertures in the
base of the equipment and the floor must be exactly
aligned. If this is not the case the equipment is not
guaranteed to operate correctly!
p
n
10
7
8
9
2
1
Fig. 5
Lead clamping strap (4) through the 2 fastening brackets (3) –
lettering on clamping strap should be facing the floor.
Position air conditioning system in stowage compartment
between brackets (2 – HW) and fastening brackets (3). Secure
air conditioning system with clamping strap (4). Ensure that
the clamping strap is in the provided recesses on the device.
Guide clamping strap (4) through buckle (6) as shown in illus-
tration and tighten.
The air conditioning system must be attached at all
sides using the brackets provided in order to prevent
unintentional movement if vigorous movements occur (e.g.
hard braking).
Attach the two floor grilles (5) for "LE" and "LA" to the floor
of the vehicle from below with suitable screws or clips (not
provided).
Cold air distribution and circulated air
return

Cold air distribution

A KR 65 cold air duct with a diameter of 65 mm (10) and at
least one outlet must be connected to all three cold air outlets
of the device (7, 8 + 9).
Slide the cold air ducts (10) into the cold air outlets of the
device and route to the air outlet nozzles. Ensure that the cold
air ducts are firmly seated in the cold air outlets. For noise
reduction purposes, Truma can supply a sound muffler for in-
stalling in the cold air system (part no. 40090-00038).
The swivel air outlet SCW 2 (black – part no. 39971-01
or beige – part no. 39971-02), the end outlet EN-O
(part no. 40171-07) with lamella inset LA (part no.
40721-01/02/03/04/05) or the rectangular air outlet RL (part
no. 40280-01) with connector piece ANH (part no. 40290-02)
would be suitable as an outlet for the cooled air into the vehi-
cle interior.
4
6
4
3
3
11
LE
LA
5