Technical data
Determined on the basis of EN 14511 or Truma test conditions
Power supply
230 V – 240 V , 50 Hz
Power consumption
Aventa compact:
Aventa compact plus:
Starting current
Aventa compact:
Aventa compact plus:
Appliance fuse (230 V)
Aventa compact:
Aventa compact plus:
Cooling power
Aventa compact:
Aventa compact plus:
Air volume flow
Aventa compact:
Aventa compact plus:
Usage limits
+16 °C to 40 °C
Maximum angle during operation
8 %
Weight
inclusive installation materials
Aventa compact:
27,5 kg
Aventa compact plus: 29.5 kg
Dimensions (W x H x D)
External: 560 x 265 x 785 mm
Internal: 523 x 46 x 670 mm (air distributor)
Internal: 496 x 46 x 556 mm (air distributor small)
Refrigerant
Aventa compact:
Aventa compact plus:
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global Warming Potential (GWP)
1774
CO2 equivalent
Aventa compact:
638.6 kg
Aventa compact plus: 833.3 kg
Subject to technical changes.
2.8 A
4.4 A
20 A (150 ms)
28 A (150 ms)
T 5 A H (slow)
T 6.3 A H (slow)
1.7 kW (T35 / T35)
2.2 kW (T35 / T35)
max. 370 m³/h
max. 400 m³/h
R 407C / 0.38 kg
R 407C / 0.47 kg
Installation dimensions (in mm)
Figure 8
192
(212)
310
Figure 9
*
air distributor small
Clearance around the air conditioning system
The clearance around the external unit must be 20 mm at
the front and 50 mm at the side. At least 20 mm of clearance
must be left at the rear. Truma recommends clearance of
50 mm so that the exhaust air can blow out freely.
Figure 10
The clearance around the air distributor must allow the air
to blow out without obstructions. The side clearance must be
at least 40 mm (not in the case of the air distributor small).
The pivoting range of flaps and doors must be taken into
consideration.
785
670
556*
400
(380)
EN
17