GB
Motor defective
Motor /fan jammed
Motor fan loose
Low flow alarm calibration altered
Defective Electronics
Air outlet blocked
Hose problems
Possible reason
Splits in hose
Holes in hose
Torn hose
Bayonet O-rings missing
Bayonet O-ring damaged
Bayonet Pins broken
Battery problems
Possible reason
Case split
Cells loose
Not locking in Power unit body
Stuck in Power unit body
Not charging
Loose socket
Intermittent contact
Reduced capacity
Battery charger problems
Possible reason
No LED illuminating
Damaged Phono plug
Damaged case or Pins
Damaged lead
IRL
Bearing/Electrical failure
Mechanical failure
Mechanical failure
Misuse/abuse or
Electronics failure
Misuse/abuse
Electronics failure
Foreign object in outlet
Possible cause
Misuse/abuse. Solvent attack
Weld splatter. Solvent attack Replace hose assembly
Misuse/abuse
lost
Wear & tear or Misuse/abuse Replace o-rings
Misuse/abuse
Possible cause
1. Misuse/abuse (Dropped)
2. Poor joint bond
Misuse/abuse or
Overheated during charging Replace battery
Battery locking mechanism
missing/defective
Battery locking mechanism
defective
Internal electrical open
circuit or Defective cells
Misuse/ abuse
Damaged or dirty contacts
on battery or power unit
1. Excessive overcharging
2. Old age
3. Incorrect charger being used
(Undercharging)
Possible cause
1. Battery defective
2. Charger defective
3. No mains supply
Misuse /abuse
Misuse /abuse or
Excessive overheating
Misuse /abuse
Replace power unit
Replace power unit
Replace power unit
Replace power unit
Replace power unit
Remove object.
Action
Replace hose assembly
Replace hose assembly
Replace o-rings
Replace hose assembly
Action
Replace battery
Replace battery
Replace battery
Replace battery
Replace battery
Clean contacts
1. Replace battery
2. Replace battery
3. Use correct charger
Action
1. Replace Battery
2. Replace charger
3. Re-instate mains supply
Replace charger
Replace charger
Replace charger
11