9.2 Sofware interface

9.2.1 Minimum system requirements

The supplied Pan & Tilt controlling software supports
up to 16 channels. The software requires Windows
XP Service Pack 3 or higher and a PC with an Xeon
processor at 2.3GHz or higher.
9.2.2 Configuration procedure through
software
Once the pan & tilt has been preset and configured,
start configuring the IP parameters (7.4.6 Connection
of the Ethernet cable, page 19).
The IP address of the various units should be
configured using a PC.
Set the IP address of the PC: 192.168.10.1 (or
192.168.10.2, etc.).
Connect the unit to the LAN network, provide power
supply and start the browser (minimum Microsoft
Internet Explorer® 6.0).
To set the IP address of the various units,
power them, taking care to connect them
one at a time to the LAN (switch/hub).
Configure the unit and insert the settings
for at least the IP address and host name.
Once configured, connect the Ethernet
cable and go on to configure the next unit.
Enter address: 192.168.10.100.
You will be asked login and password. When making
the settings for the first time insert the default login
and password.
• Login: admin
• Password: 1234
44
The Pan & Tilt control interface is displayed if login is
successful.
Fig. 84
The P&T can work via ONVIF or TCAM
protocol. In the event the ONVIF protocol is
used, make sure to set the time correctly in
the device or to configure an NTP server. (
9.3.5 Network Configuration, page 48).

9.2.3 Installing the software

Insert the CD and start the autoplay or launch the
installer. A web page opens for the installation of the
TVMS server application (32 or 64 bit, based on the
computer's features).
You will be asked login and password. When making
the settings for the first time insert the default login
and password.
• Login: admin
• Password: 1234
Select Camera from the Setup menu to add the
device to the VMS.
Fig. 85