7.6.3 Setting the configuration check
mode (DIP 1)
SW 1=ON: Display Configuration. To be used only to
verify the configuration at the end of the setting. To
be used only to verify the configuration at the end of
the setting. During normal operation make sure the
lever is on OFF (SW 1=OFF).

7.6.4 Baud rate configuration

To set the baud rate operate on DIP 1.
Switches 4, 3 and 2 are used to select the
communication rate of the device.
BAUD RATE CONFIGURATION (DIP 1)
Baud rate
ON ON ON –
selection
OFF ON ON –
ON OFF ON –
OFF OFF ON –
ON ON OFF –
OFF ON OFF –
ON OFF OFF –
OFF OFF OFF –
Configurations
ON –
display
OFF –
Tab. 7
MNVCUCZ_1511_EN
38400 baud
19200 baud
9600 baud
4800 baud
2400 baud
1200 baud
600 baud
300 baud
Display
enabled
Display disa-
bled
7.6.5 Setting of the serial
communication lines
To set the serial communication lines operate on
DIP 1.
The product is provided with the following serial
communication lines:
• RS-485: 2 lines
The serial lines configuration must be carried on
through the following dip-switches:
• DIP 1: SW 5-SW 6
SETTING OF THE SERIAL COMMUNICATION LINES (DIP
1)
Serial line
ON ON –
OFF ON –
ON OFF –
OFF OFF –
Tab. 8
Two-way RS-485 TX/
RX line
Line RS-485-1 recep-
tion, line RS-485-2
repetition
Two-way RS-422 line
One-way RS-485 line
21