Replacement of the front panel

 Re-attach the front panel, insert the fastening screws on the top (short) and bottom
(long) and tighten them crosswise (torque of 3 Nm).
 Re-attach the mains lead (pos. 10).
417102213_EDP L_V15.docx
Fig. 10.12
 Unplug the mains lead (pos. 10).
 Loosen the front fastening screws (pos. 1) at the
top (short) and bottom (long). (There is no need to
loosen the fastening screws in the middle on the
front panel).
 Remove the front panel (pos. 2).
 Unplug the motor control line connector (pos. 4)
from the board.
 Disconnect the position sensor connection line
connector (pos. 3) from the board.
 Take hold of the front panel and re-establish all
the plug-in connections.