Design and description of the components

Block diagram
Fig. 4.1
Connexx Basic or Connexx Switch systems are installed between the suction connection of
the metering pump(s), and the container suction pipe. They the detect the empty level and
provide venting for disinfection products liable to gas (see chapter 1).
Two containers can be connected to Connexx Switch. When one container is detected as
being empty, the system switches over to the other one automatically. The switchover
function can also be retrofitted to Connexx Basic by adding a valve module (see
Accessories, chapter 9.2).
An oil-free compressed air connection at 3.5 to 6 bar and a vent line connection of at lest
DN20 are needed in addition to a 230 V 50/60 Hz power supply.