Instantaneous water heater for Regudis W-HTE

Mounting

3.4

Installation scheme

1
9
Illust. 2:
Installation scheme
1
Hot water outlet Regudis W-HTE
2
Cabinet
3
Flow sensor
4
Regudis W-HTE
5
Ball valve connection set for Regudis
W-HTE
6
Heating circuit supply
7
Heating circuit return
8
Multidis SF heating circuit distributor/
collector
9
Instantaneous water heater
3.5

Technical data

Please note the separately enclosed
documents.
18
2
3
4
5
6
7
8
4. Mounting
Mounting the instantaneous water heater in
Oventrop cabinets is described in these
operating instructions.
The instantaneous water heater is
suitable for wall mounting and for
integrated mounting in Oventrop
cabinets (OV item no. 1344599 and
1344699).
For wall mounting, please observe the
enclosed "Assembly instructions for
qualifi ed tradespeople".
WARNING
Danger to life due to electric current
Danger to life due to contact with live
components.
f
Completely disconnect the product from
the power supply.
f
Check that no voltage is present.
f
Secure the product against switching
back on.
f
Only install the product in dry indoor
areas.
CAUTION
Risk of scalding due to hot fl uids
If the station was in operation, there is a risk
of scalding due to the unintentional
discharge of hot water or steam.
f
Allow the system to cool down.
f
Wear suitable protective clothing.
CAUTION
Risk of burns due to hot components
Any unprotected contact with hot
components may lead to burns.
f
Allow the system to cool down.
f
Wear safety gloves.