Flow temperature control module
(1) Indicator mark
(2) Figure
(4) Handgrip
(3) Memo disk
Control range
Figure
1
2
3
4
5
6
Further information can be obtained from
the operating instructions supplied with the
temperature controller.
3.4.2
Contact thermostat
A contact thermostat for the additional protection
of the surface heating system against excess
temperatures is supplied with the flow temperature
control module.
Further information can be obtained from
the operating instructions supplied with the
contact thermostat.
3.5
Technical data
Max. operating pressure p s
Max. operating temperature t s
primary side
Max. operating temperature t s
secondary side
Control range temperature
controller
Control range contact thermostat
134455080-V04.01.2020
Temperature
about 25°C
about 30°C
about 35°C
about 40°C
about 45°C
about 50°C
10 bar
90°C
50°C
25°C-50°C
20°C-90°C
Accessories and spare parts
4.
Accessories and spare parts
The heating circuit connection fitting, item no.
1344551, can be used for the additional connection
of radiators.
5.
Transport and storage
Transport the product in the original packaging.
Store the product under the following conditions:
Temperature
-20°C to +60°C
range
Relative
max. 95%
humidity of air
Particles
Dry and free from dust
Mechanical
Protected from mechanical
agitation
influences
Radiation
Protected from UV-rays and direct
sunlight
Chemical
Do not store together with
solvents, chemicals, acids, fuels
influences
and similar
6.
Installation
6.1
Setting of the maximum flow
temperature at the contact
thermostat
1. Loosen the screw at the casing.
2. Remove the cover.
3. Select a temperature (e.g. 60°C for concrete and
calcium sulphate screed)
4. Connect the contact thermostat electrically
according to the enclosed instructions.
Illustr. 7: Settings contact thermostat
19