Installation instructions, for professionals only

4.2. Installing the control unit

The control unit 2 of the infrared controller is installed on the outside wall of the
cabin with a maximum clearance of 10 metres from the power supply unit 1 (see
Fig. 2). For the installation, a standard jigsaw is required to cut out the recess for
the control unit. The control unit can be installed both inside and outside the cabin.
* For installing inside an infrared cabin, a minimum clearance of 30 cm
must be maintained (see Fig. 2 Control unit position on page 11).
ATTENTION!
Damage to the unit
● The control unit 2 of the infrared controller is splashproof (protection
class IP X4).
● Work on the control unit must only be carried out using a standard screwdriver.
Using a cordless screwdriver may cause irreparable damage to the housing.
1
min. 30 cm
Control
2
unit
Fig. 2 Control unit position
* for assembly inside the cabin
Power unit
Infrabox
*
External view
p. 11/44