Instructions for installation and use
13. Technical data
Operating unit
Connection: 4-pin with power supply and communication lines
Mains voltage:
Output:
Storage temperature:
Ambient temperature:
Relative humidity:
Dimensions: L x W x D
Power unit
Nominal voltage
Dimensions
Connection cable
Contact rating / heater
Leading edge phase control
Half-wave control
Switching
Ambient conditions
Light/fan power
Thermal safety
Adjustable automatic heating period (6 h, 12 h, 18 h, 24 h)*
* EN 60335-2-53 specifies a heating time limitation of 6 h for private saunas. For saunas in hotels,
apartment blocks and similar locations, a maximum heating period limit of 12 hours is permissible.
Extending the heating period limit to 18 hours or 24 hours is only permitted in public saunas.
5 V DC
<0.5 W
-25 °C to 70 °C
-10 °C to +110 °C
max. 99% rel. humidity,
non-condensing!
100.1 x 63.1 x 36.6 mm
230 VAC
195 x 119 x 48 mm
3 x 1.5 mm² for light,
Electronics and heating elements
350 W
1.3 kW
3.5 kW
10 °C to +40 °C
100 W
p. 43/44
EN