3) Visualisation of the
The intervention of the Technical Assistance Service is required.
NOTE
fault on domestic circuit probe - 60 (only present when an
external storage tank with probe is connected): the boiler operates
normally
but does not guarantee a stable temperature for the water
in the domestic circuit; in any case, it is supplied at a temperature
of about 50°C.
The fault code is only visualised in standby operation.

Programming the parameters

This boiler is fitted with the latest type of electronic cards, allowing you to
set/modify the machine operating parameters and thereby offering a more
personalised configuration to meet the various system and/or user needs.
The programmable parameters are the ones indicated in the
"PROGRAMMABLE PARAMETERS" table.
The parameter programming operations must be carried out with the
boiler in the OFF position.
To do this, press the
key until you see "- -" on the display (Fig.26).
During the parameter modification operations, the "function selection"
key acts as an ENTER key, while the key acts as an ESCAPE key.
If no confirmation is given within 10 seconds, the value is not
memorised and the previous one is again indicated.
Setting the password
Press the operation mode key and the
10 seconds.
The screen appears as in Fig.27.
Enter the password for accessing the parameter modification functions,
turning the domestic water temperature selector until the required value
is shown.
The password for parameter programming access is located inside the
command panel.
Confirm the input by pressing the ENTER key.
Modifying the parameters
Turn the domestic water temperature selector (Fig.28) to scroll - in sequence
- through the two-figure codes of the parameters indicated in the table.
Identify the parameter you want to modify in the following way:
- press the ENTER key to be able to modify the parameter value.
When you press the ENTER key, the old value will flash (Fig.29)
- turn the domestic water temperature selector until the required value is
indicated
- confirm the new value by pressing ENTER. The digits will stop flashing
- quit by pressing ESCAPE
The boiler goes into "- -" mode (OFF).
To restore operation, press the
and
icons (fig.25)
key simultaneously for about
key.
Fig.24
Fig.25
Fig.26
ENTER
Fig.27
Fig.28
parameter value
Fig.29
ESCAPE
parameter number
13