Parametri programabili
NR.
DESCRIERE PARAMETRU
PAR.
1
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
2
PARAMETRU NESEMNIFICATIV
3
GRAD DE IZOLAŢIE AL CLĂDIRII
10
MOD PREPARARE A.C.M.
11
TEMPERATURĂ MAXIMĂ SETABILĂ CIRCUIT ACM
12
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
13
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
14
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
20
MOD ÎNCĂLZIRE
21
SET-POINT MAXIM ÎNCĂLZIRE
22
SET-POINT MINIM ÎNCĂLZIRE
23
VITEZĂ MAXIMĂ VENTILATOR CIRCUIT ÎNCĂLZIRE
24
VITEZĂ MINIMĂ VENTILATOR CIRCUIT ÎNCĂLZIRE
25
DIFERENŢIAL ÎNCĂLZIRE POZITIV
26
DIFERENŢIAL ÎNCĂLZIRE NEGATIV
28
TEMPORIZARE PT. REDUCERE PUT. MAX. ÎNCĂLZ.
29
TEMPORIZARE PT. OPRIRE FORŢATĂ ÎNCĂLZIRE
30
FUNCŢIE DE RESETARE TEMPORIZARE ÎNCĂLZIRE
31
SET-POINT MAXIM ÎNCĂLZIRE 2CH (circuit 2)
32
SET-POINT MINIM ÎNCĂLZIRE 2CH (circuit 2)
40
TIP DE FUNCŢIONARE TERMOSTAT ACM
41
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
42
FUNCŢIE S.A.R.A.
43
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
44
FUNCŢIE DE TERMOREGLARE
45
ÎNCLINAŢIE CURBĂ DE TERMOREGLARE (OTC)
46
FUNCŢIE DE TERMOREGLARE 2CH
47
ÎNCLINAŢIE CURBĂ DE TERMOREGLARE (OTC) 2CH
48
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
50
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
51
TIP CERERE DE CĂLDURĂ CH1 (circuit 1)
52
TIP CERERE DE CĂLDURĂ CH2 (circuit 2)
61
TEMP. FUNCȚIONARE ANTI-ÎNGHEŢ ACM (ON)
62
TEMP. FUNCȚIONARE ANTI-ÎNGHEŢ ÎNCĂLZIRE (ON)
63
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
65
REACTIVITATE SONDĂ EXTERNĂ
85
CARICAMENTO SEMIAUTOMATICO
86
PRESIUNE DE UMPLERE SEMIAUTOMATĂ (ON)
87
PARAMETRU NEUTILIZAT LA ACEST MODEL. NU MODIFICAŢI PROGRAMAREA
90
POMPĂ VITEZĂ VARIABILĂ
92
ACTIVARE POSTCIRCULAŢIE DE LA ACM LA ÎNCĂLZ.
93
DURATĂ POSTCIRCULAŢIE DE LA ACM LA ÎNCĂLZ.
94
POMPĂ ÎN FUNCȚIONARE CONTINUĂ CIRCUIT I
95
POMPĂ ÎN FUNCȚIONARE CONTINUĂ CIRCUIT II
Unele valori implicite pot fi diferite de cele indicate în tabel, datorită nivelului de actualizare a plăcii electronice
140
UNIT. DE
MIN
MĂSURĂ
10 (10kW)
16 (16kW)
20 (20kW)
26 (25kW)
30 (30kW)
34 (35kW)
50 (50kW)
70 (70kW)
min
5
0 (OFF)
1 (instantanee)
2 (mini-acumulare)
3 (boiler extern cu termostat)
4 (boiler extern cu sondă)
5 (boiler încorporat DS)
6 (boiler încorporat 3S)
° C
40
0 (OFF)
1 (ON)
2 (NU ESTE UTILIZAT)
3 (CIRCUIT DIRECT AT sau BT)
4 (NU ESTE UTILIZAT)
5 (NU ESTE UTILIZAT)
6 (CIRCUIT AT+BT)
7 (PANOU LA DISTANŢĂ + CIRCUIT AT+BT)
8 (PANOU LA DISTANŢĂ + VANE ZONĂ)
° C
40
° C
20
rpm
METHANE LPG
50
rpm
METAN LPG
50
13(*) 16(*)
° C
2
° C
2
min
0
min
0
-
0 (NO)
° C
40
° C
20
0 (OFF)
1 (AUTO)
2 (ON)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2.5
0 (OFF)
1 (AUTO)
-
2.5
-
0
-
0
°C
0
°C
0
0 (f. rapidă)
255 (f. lentă)
0 (dezactivată)
1 (activată)
bar
0.4
-
0
-
0
-
1
-
0
-
0
MAX
IMPLICIT
(setat din
setat de
fabrică)
1
50
Power Green 50
20
5
3
60
60
60
80
5
1
80
80
39
20
MAX
58(*) 57(*)
MIN
10
6
10
6
20
15
20
5
1 (SI)
0
80
45
39
25
1
1
0
0
1
40
20
1
40
10
1
1
1
0
1
0
10
4
10
6
6
20
0
1.0
0.6
0
100
1
1
0
255
5
1
0
1
0
CSA
*
Valoarea afișată
pe display este
exprimată în
rpm / 100
(ex . 3600 = 36)