Type 8691
DeviceNet
led
device status
Flashes
Connection
red
time-Out
Red
Critical fault
Table 23:
Status of the bus LED
Status of the device status LeD
led
device status
Off
No supply
Green
Device is working
Table 24:
Status of the device status LED
Status of the pilot valve LeD
led
explanation
Off
• Pilot valve is not actuated
Yellow
• Pilot valve is actuated
Table 25:
Status of the pilot valve LED
noTe!
damage or malfunction due to penetration of dirt and humidity!
To ensure protection class IP65 / IP67:
• Screw the transparent cap in all the way.
explanation
• One or more I/O connections are in
Time-Out state
• Another device with the same MAC
ID address is in the circuit
• No bus connection due to communi-
cation problems
explanation
• Device is not supplied with voltage
• Normal operating status
troubleshooting
• New connection establishment by
master to ensure that the I/O data
is transmitted cyclically.
• Check baud rate
• If required, replace device
english