4 OPERATION

4.2 Operation Mode Display

The following variables are displayed in the operation mode:
45.6 L/ m
80529 L
6247 L.

4.3 Calibration Mode:

The ENTER key can be locked (see §5.2).
The following variables can be set in the parameter definition menu:
LANGUAGE
UNIT
K-FACTOR
FILTRE
TOTAL
FLOW INDICATOR - TOTALIZER 8025
Flow rate in the required engineering unit. The display switches
to main totalizer after 10 sec.
Main totalizer in the required engineering unit (see calibration
menu). Reset in the calibration menu.
Daily totalizer in the same engineering unit as the main totalizer.
A point behind the unit differentiates it from the main totalizer.
Reset by simultaneously pressing the
seconds.
ENTER
Language selection between English, German, French and
Italian.
Selection of engineering units to display flow rate and totalizer.
Input of K-factor according to chart or Teach-in function in order
to determine the specific K-factor.
Dampening selection. There are ten different steps available.
Totalizer resetting.
Return to function menu.
END
Selection of flow display option
Press simultaneously for 5 seconds
E-10-
keys for 2
0......9