Télécharger Imprimer la page

Error Displays Of The Tr4 Unique Coded During; Teach-In; Tab. 4: Error Displays Of The Status/Diag Led On The Tr4 - SICK TR4 Mode D'emploi

Masquer les pouces Voir aussi pour TR4:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating Instructions
TR4
Tab. 4: Error displays of
the Status/Diag LED on
the TR4 Unique Coded
during teach-in
Note
8014465/YIJ2/2015-03-02
Subject to change without notice
Commissioning
6.2.3

Error displays of the TR4 Unique Coded during

teach-in

Display of the
Status/Diag LED (4 Hz)
Green
8 ×
Green
3 × Red,
1 × Green
3 × Red,
2 × Green
3 × Red,
3 × Green
3 × Red,
4 × Green
3 × Red,
5 × Green
The error indications are repeated until the device is reset.
To reset the device, disconnect the voltage supply to the device for at
least 3 seconds.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Meaning
OSSD inputs invalid or not present
An actuator has not yet been taught-in
(default delivery status)
It is intended to teach-in a Multicoded
actuator. This is not possible.
It is intended to teach-in again an actuator
that has already been taught-in previously.
This is not possible.
The actuator has been moved out of range
(RFID signal interrupted).
Eight actuators have been taught-in.
A further teach-in process is not possible.
The device has been locked. A further
teachKin process is not possible.
en
Chapter 6
75

Publicité