Télécharger Imprimer la page

Fig. 1: Response Range With M18 Actuator; Fig. 2: Response Range With M30 Actuator - SICK TR4 Mode D'emploi

Masquer les pouces Voir aussi pour TR4:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating Instructions
TR4
Fig. 1: Response range
with M18 actuator
Fig. 2: Response range
with M30 actuator
8014465/YIJ2/2015-03-02
Subject to change without notice
Mounting
Off
Side approach
Off
Side approach
If the actuator moves laterally in relation to the surface of the sensor,
a minimum distance of 4 mm (with M18 actuator) or 7 mm (with
M30 actuator) must be maintained. This distance will prevent pre-
mature triggering due to the side approach areas.
If necessary fit an additional protective stop for the moving part of
the guard.
Pay attention to the maximum tightening torque for fastening the
sensor and actuator of 2.3 Nm.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Safe switch-on distance 15 mm
Off
On
Offset [mm]
Safe switch-on distance 25 mm
Off
On
Offset [mm]
en
Chapter 4
Side approach
Side approach
61

Publicité