Télécharger Imprimer la page

Dimensional Drawings; Dimensional Drawing Tr4 Direct Sensor; Tab. 6: Data Sheet Tr4; Fig. 13: Dimensional Drawing Tr4 Direct Sensor (Mm) - SICK TR4 Mode D'emploi

Masquer les pouces Voir aussi pour TR4:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

en
Chapter 9
Outputs
2 OSSDs (Out A and Out B)
Auxiliary contact (Aux)
Surrounding
Ambient operating
temperature
Relative air humidity
Enclosure rating
Vibration resistance
Shock resistance
EMC
UL Listed Ratings
Standards
Power Supply
Ambient Temperature
Enclosure Rating

Tab. 6: Data sheet TR4

Fig. 13: Dimensional
drawing TR4 Direct
sensor (mm)
86
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical specifications
Minimum
2 × PNP, 0.2 A max., short-circuit-proof and overload-proof
1 × PNP, 0.2 A max., short-circuit-proof and overload-proof
–10 ... +55 °C
5 %-95 %
IP 69K
3.5 mm/10-55 Hz (EN 60 068K2K6)
30 g, 11 ms (EN 60 068K2K27)
According to IEC/EN 60 947-5-3
UL 508, CSA C22.2 No. 14
20 ... 30 V DC, Class 2
+40 °C max.
Type 3, 4X, 12, 13
9.3

Dimensional drawings

9.3.1

Dimensional drawing TR4 Direct sensor

2.03
Typical
67.06
M18×1
Operating Instructions
TR4
Maximum
8014465/YIJ2/2015-03-02
Subject to change without notice

Publicité

loading