Télécharger Imprimer la page

Publicité

Les langues disponibles
  • FR

Les langues disponibles

en
Chapter 4
4

Mounting

WARNING
Note
60
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Mounting
Mounting is only allowed to be performed by authorized specialist
personnel!
Mounting must be undertaken in accordance with the following notes
and the stated specifications and is to be undertaken by appropriately
qualified persons.
Follow the following mounting instructions. Otherwise the warranty will
be rendered void.
This device is part of a protective device for the protection of a ma-
chine. Prior to mounting a risk analysis should be undertaken to deter-
mine whether this device's specifications are suitable for all foresee-
able operating and environmental parameters at the machine in which
it is to be installed.
Steps for mounting the device
Select mounting position for the safety switch such that the sensor
and actuator are easily accessible for inspection and replacement,
and are protected against damage.
Ensure that a hazard is also excluded if the actuator has yet not
reached the safe switch-off distance on opening the guard.
Pay attention to EN ISO 14 119:2013, sections 5.2 and 5.3, on
mounting the safety switch and the actuator.
Pay attention to EN ISO 14 119:2003, section 7, on reducing
possible ways of bypassing an interlocking device.
Mount the actuator on the moveable part of the guard.
Mount the sensor on the fixed part of the guard.
Align the sensor and actuator in relation to each other such that their
front faces are within the switch-on distance of 15 mm (with M18 ac-
tuator) or 25 mm (with M30 actuator) apart when the guard is closed
(see Fig. 1 and Fig. 2).
Operating Instructions
TR4
8014465/YIJ2/2015-03-02
Subject to change without notice

Publicité

loading