The machine will recover the residual refrigerant into the service hoses, then the following
screen will be displayed:
Close HP and LP valves and press ENTER.
A summary of the amount gas of the CHARGE phase is displayed.
Press the symbol
CHARGE procedure is now successfully completed, press PRINTER to print the receipt of the
procedure, press ENTER to return to exit.
NOTE: near the end of the charge could be displayed the following alarm message:
The SLOW CHARGE alarm occurs when the tank pressure and the system pressure equalize
(due to low pressure, excessive system temperatures, etc.). Check connections then press
ENTER to continue, or press ESC to exit.
INSTRUCTIONS MANUAL
EMPTY HOSES
EMPTY HOSES
Hoses pressure
CHARGE
Close HP and LP valves
END of procedure
Gas charged:
Press ENTER to continue
for printing
SLOW CHARGE
Check connections
Press ENTER to continue
Press ESC to exit
DD/MM/YY XX:XX PM
4.0bar
STOP
DD/MM/YY XX:XX PM
ENTER
DD/MM/YY XX:XX PM
200 g
ENTER
DD/MM/YY XX:XX PM
ESC
ENTER
-54-