At the end of this phase, the machine will test for leaks in the A/C system:
(WARNING! If vacuum time is lower than 15 minutes this test is not reliable). If leaks are found,
the machine will stop automatically and display the A/C SYSTEM LEAKS alarm.
Detection of micro-leaks is not guaranteed.
At the end of the preset vacuum time, the machine will sound and alarm and the following
screen will be displayed:
Set HVAC blower motor on low, A/C switched off, air distribution mode set to "flor2, then press
ENTER to continue
Put a SAE J2913 compliant leak detector set to high-maximum sensitivity (4g/year) into the
center of a floor duct outlet, as far as possible, then press ENTER to continue
A pop-up message is displayed asking confirmation, press YES or NO to continue:
INSTRUCTIONS MANUAL
VACUUM
0:51 min
CHECK LEAKS
A/C pressure
-0.99 bar
HVAC blower motor on low,
A/C switched off, air distribution
Mode set to "floor"
Put a SAE J2913 compliant leak detector
set to high-maximum sensitivity (4g/year)
into the center of a floor duct outlet, as
far as possible
Was this test performed?
YES
0g
CHARGE AMOUNT
-51-
DD/MM/YY XX:XX PM
STOP
DD/MM/YY XX:XX PM
ENTER
DD/MM/YY XX:XX PM
ESC
ENTER
DD/MM/YY XX:XX PM
NO
0g
CHARGE AMOUNT