Open manual valves and press ENTER.
When time of check is reached, the machine will test for leaks in the A/C system:
(WARNING! If vacuum time is lower than 15 minutes this test is not reliable). If leaks are found,
the machine will stop automatically and display the A/C SYSTEM LEAKS alarm.
Detection of micro-leaks is not guaranteed.
At the end of the preset vacuum time, the machine will sound and alarm and the following
screen will be displayed:
Close and disconnect HP and LP coupling from A/C system, then press ENTER to return to the
MAIN MENU; VACUUM PROCEDURE is now successfully completed.
INSTRUCTIONS MANUAL
Open HP and LP valves
Press ENTER to continue
VACUUM
1:37 min
VACUUM
A/C pressure
-0.99 bar
VACUUM
0:51 min
CHECK LEAKS
A/C pressure
-0.99 bar
Close and disconnect HP and LP couplings
from A/C system and press ENTER