1. Provide a new dust collection bucket.
2. Switch off the product using the on/off switch.
3. Set the main switch to 0 and secure it against unintentional restarting.
4. Release the clamp fastener (item 12) while holding the dust collection
bucket (item 11) securely and securing it against falling.
5. Close the dust collection bucket with the clamp fastener and cover of
the new dust collection bucket and dispose of it according to the
instructions.
6. Insert the new dust collection container and close it airtight with the
clamp fastener.
7. Put the product back into operation. See chapter "Commissioning".
7.4 Draining the compressed air vessel condensate
Depending on usage, but at least once a month, the condensate must be
drained from the compressed air vessel.
The condensate can be drained during operation. The product must be
connected to the compressed air network and air pressure must be
applied.
To drain the condensate, please proceed as follows:
1. Hold a suitable container under the condensate valve outlet opening
(item 8) and slowly open the valve by hand.
1502518-00
Fig. 44: Draining the condensate
- 91 -
EN