Load Of The Wall Console Due To The; Extraction Arm - Kemper 79 807 Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
1.5
Load of the Wall Console due to the Extraction Arms
Extraction
Note
arm length
[m]
4 m cantilever
6
+
2 m arm
4 m cantilever
7
3 m arm
4 m cantilever
8
+
4 m arm
6 m cantilever
8
+
2 m arm
6 m cantilever +
9
3 m arm
6 m cantilever
+
10
4 m arm
*1 rounded values
Art. Nr.: 1502199
General Assembly
DANGER
Falling components may cause life-threatening injuries
Improper fittings may cause the extraction arms to fall and
cause life-threatening injuries.
● Mount the extraction arm with the hinged cantilever only
onto walls and columns with a sufficient load capacity.
● Ensure that the column is anchored firmly into the
ground
Torque at the
*1
wall console
[Nm]
5,430
5,565
5,760
9,350
9,555
9,850
Tensile force per
upper
*1
mounting screw
[N]
[kg]
5,325
545
5,455
555
5,650
575
6,620
675
6,765
690
6,975
710
1-3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

79 80879 40979 30779 308

Table des Matières