- General utility programmes:
• calibration
• service
• diagnostics.
- Power voltage ........................... single phase 100/115 V ±10%, 200/230 V ±10%, 50/60 Hz
- Rated power ................................................................................................................... 200 W
- Rated current .............................................................. 1.8 A at 100/115V, 0.9 A at 200/230V
- Maximum unbalance value calculated ................................................................ 999 grams
- Average spin time (with 5"x14" wheel) ......................................................................... 7 sec
- Shaft diameter ............................................................................................................. 40 mm
- Ambient work temperature ...................................................................................5° to 40°C
Machine dimensions (Fig. 9/9a)
User manual ProLine 640
TECHNICAL DATA
UK
9