Video Cable Connection; I/O Cable Connection; Connecting The Telemetry Line; Two-Way Rs-485 Tx/Rx Line - Videotec MAXIMUS MVXT Manuel D'instructions

Caméra thermique analogique antidéflagrante compacte à haute performance
Masquer les pouces Voir aussi pour MAXIMUS MVXT:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 69

4.3 Video cable connection

CDS installation type (Cable Distribution
System). The installation is type TNV-1, do
not connect it to SELV circuits.
Depending on the version, the video cable requires
the following type of connector:
• Multipolar armoured cable version: RG 179/U
• Cable tail version: RG 59B/U

4.4 I/O cable connection

CAUTION! TNV-1 installation type. The
installation is type TNV-1, do not connect it
to SELV circuits.
The shielding of the I/O cable must be
grounded.
I/O CABLE CONNECTION
Colour
Function
White
RS-485 A (+)
Yellow
RS-485 B (-)
Pink
Relay 1, Terminal A
Blue
Relay 1, Terminal B
Brown
Alarm/Digital input
Green
GND/Common alarm
Grey
Reset
Tab. 4
MNVCMVXTCAM_2121_EN

4.4.1 Connecting the telemetry line

The product has an RS-485 serial communication
line. It can be used for control by keyboard and PC
programming.
It is not necessary to configure the
device communication protocol. The
protocol used is automatically recognised
(PANASONIC 850, PELCO D, MACRO).

4.4.1.1 Two-way RS-485 TX/RX line

With this setting it is possible to obtain a bi-
directional, half/duplex, communication on the
RS-485 line.
Default speed: 38400Bd.
If necessary, change the default value of the RS-485
line, which can be done using the PTZ Manager
software available to download for free on the
website support.videotec.com.
Fig. 1
RS-485
TX/RX
9

Publicité

Table des Matières
loading

Table des Matières