6.1.4.5 Gain Switch Values

It allows you to configure the following parameters:
High-Low threshold: Sets the temperature
1.
threshold used by the High-Low Percentage
parameter to force the switching in Low Gain
mode. The value is indicated in Celsius degrees.
2.
High-Low percentage: Sets the minimum
pixel percentage above which the switching in
Low Gain mode is carried out.
3.
Low-High threshold: Sets the temperature
threshold used by the Low-High Percentage
parameter to force the switching in High Gain
mode. The value is indicated in Celsius degrees.
Low-High percentage: Sets the minimum
4.
pixel percentage above which the switching in
High Gain mode is carried out.
GAIN SWITCH VALUES
GAIN SWITCH VALUES
------------------------
------------------------
1>HIGH-LOW THRESHOLD:120
1>HIGH-LOW THRESHOLD:120
2 PERCENT. HIGH-LOW : 20
2 PERCENT. HIGH-LOW : 20
3 LOW-HIGH THRESHOLD:100
3 LOW-HIGH THRESHOLD:100
4 PERCENT. LOW-HIGH : 95
4 PERCENT. LOW-HIGH : 95
Fig. 24
We recommend that you do not change
the default values which have been set
to guarantee high quality images in any
operating condition.
Change Gain Values menu settings only
take effect if the Gain Mode has been set
to Auto (6.1.4.4 Flat Field Correction Menu,
page 18).
MNVCMVXTCAM_2121_EN

6.1.4.6 Digital Data Enhancement menu

This menu allows configuration of the Digital Data
Enhancement (DDE) algorithm.
1.
DDE Mode: The DDE algorithm can be used to
improve the details of the image and/or remove
noise. Displays the parameters of the selected
mode (Dynamic or Manual).
Dynamic: DDE parameters are automatically
calculated according to the scene content. DDE
Index is the only control parameter.
2.
DDE Index: This is the control parameter for
DDE Dynamic Mode. If the value is set to 0 no
image processing will take place. Values below
0 filter noise. Values greater than 0 enhance the
details of the image.
DIGITAL DATA ENHANCEMENT
DIGITAL DATA ENHANCEMENT
------------------------
------------------------
1>DDE MODE
1>DDE MODE
2 DDE INDEX
2 DDE INDEX
Fig. 25
:DYNAMIC
:DYNAMIC
:
:
0
0