9.2.2 Video cable connection

CAUTION! In order to reduce the risk of fire,
only use cables with sections greater than
or equal to 0.14mm² (26AWG).
We suggest the following coaxial cables:
• RG59
• RG174A/U UL1354
Use of Ethernet cables with the following
characteristics is highly recommended:
• STP (shielded)
• Category 5E (or higher)
9.2.2.1 Video cable connection (analog
output signal)
The video cable leading out of the housing must
be connected to the analog video output (J8, 8.4
Connector board description, page 21).
9.2.2.2 Video cable connection (IP generic
camera)
Do not connect RS-485 cable and the video
cable when using an IP camera.
The Ethernet network cable leading out of the
housing must be connected directly to the generic
IP camera.
Fig. 19
9.2.2.3 Video cable connection (digital
output signal)
Do not connect RS-485 cable and the video
cable when using an IP camera.
The Ethernet network cable leading out of the
housing must be connected to the digital video
output (J1, 8.4 Connector board description, page 
21).
MNVCMVXTHD_1813_EN

9.2.3 Signal cable connection

CAUTION! TNV-1 installation type. The
installation is type TNV-1, do not connect it
to SELV circuits.
Use a shielded multipolar cable. Connect
the braiding of the shielded cable to
terminal 8 (J11, Tab. 13, page 25).
The output signal cables must be connected to the
connector for the relays, alarms, serial line, factory
default (J11, 8.4 Connector board description, page 
21).
DESCRIPTION OF THE TERMINAL (J11)
Terminal contacts
Function
1
RS-485 A (+)
2
RS-485 B (-)
3
Relay 1, Terminal A
4
Relay 1, Terminal B
5
Digital input
6
GND
7
Reset
8
Shield
Tab. 13

9.2.3.1 Serial line connection

The product has an RS-485 serial communication line,
Half-duplex, Internally terminated (switch 4 of the
DIP1 is positioned by default ON).
The setting may need to be changed for analogue
camera versions. Position switch 4 of the DIP1 OFF to
configure line RS-485 as Not terminated internally (
8.3 Control board description, page 21).
Connect the serial line to the relay connector, alarms,
serial line, factory default (J11, terminal 1/terminal 2,
8.4 Connector board description, page 21).