Note: If the key function is selected for the zone 5,
GB
the mode "Full" must be programmed.
15) To confirm press the button Yes. The display e.g.
shows:
Zone
1 Text
Z o n e 1
16) The characteristic of the zone is shown in the
lower display line. The default setting is: "Zone"
and the number of the zone. For keeping the
default setting press the button Yes and continue
with the operating step 19.
For indicating another characteristic press the
button No. The display shows:
Zone
1 Text
-
17) With the numerical keys enter 16 letters, numbers,
and, if necessary, blanks. Press the corresponding
numerical key so many times until the desired
character appears:
Button Character
1
A, B, C
2
D, E, F
3
G, H, I
4
J, K, L
5
M, N, O
If the desired character is displayed, actuate the
button Yes and enter the next letter. If not all 16
characters are required, complete the remaining
positions with blanks.
18) As soon as the 16th character is confirmed with
the button Yes, the display goes to the settings for
the next following zone. Repeat the operating
steps 12) to 17) for all zones used.
19) To exit the level for the zone settings, press the
button 0. The display shows:
Program .......
Zones ?
5.2 Entry delay and exit delay
Signalizing when activating
Quick activation
20) Starting from the operating step 19) of the pre-
vious chapter press the button No. The display
shows:
Program .......
Exit/Entry ?
21) Press the button Yes. The display shows:
F-Exit
3 0
"F-Exit Time" is the exit delay time in the activa-
tion mode "Full" (all zones activated). 30 seconds
are programmed as a default setting. For keeping
this delay time press the button Yes.
30
Button
6
7
8
9
Y, Z, blank
0
1, 2, 3, ... 9, 0
Time
No. The display changes to:
F-Exit
0 0< —
Enter a time between 00 and 99 seconds with the
numerical keys. A wrong input can be corrected by
writing over it.
22) To confirm the selected time, press the button Yes
The display changes to:
F-Exit
T i m e
Press the button No so many times until the re-
quired mode for the exit delay time is displayed:
Time
The exit delay time ends after the time adjusted
before.
T/EE (Time or Entry/Exit)
The exit delay time either ends after the time ad-
justed before or if a recording was made in a zone
Character
with the feature "E/E".
P, Q, R
ET (Exit Terminator)
S, T, U
The exit delay time will not end before a recording
is made in the zone with the feature "ET".
V, W, X
E/E (Entry/Exit)
The exit delay time will not end before a recording
is made in a zone with the feature "E/E".
23) To confirm the selected mode, press the button
Yes. The display changes to:
P-Exit
T i m e
"P-Exit Time" is the exit delay time in the activa-
tion mode "Part..." (certain zones are deactivated).
30 seconds are programmed as a default setting.
For keeping this delay time, press the button Yes.
time are programmed as for the activation mode
"Full" (see operating steps 21 and 22).
24) To confirm the selected mode, press the button
Yes. The display changes to:
P-Exit
A u d .
Press the button No so many times until the de-
sired mode for the acoustical signalizing of the
exit delay time in the activation mode "Part ..." is
displayed:
Aud.
During the exit delay time an audio signal sounds
continuously. Adjust the volume for the speaker
with the control VR1 (8). However, in case of an
alarm the speaker will always sound at maximum
volume.
Silent
During the exit delay time no audio signal will
sound. When the time has expired, however, a
short signal will sound.
To programme another time, press the button
Time
Mode
Mode
Another time and the mode for the exit delay
Sounder