Please unfold page 3. Then you can always see the
operating elements described.
1 Component Parts
1.1 Inside view (fig. 1)
1 Terminal strip TB5 for the power supply
2 x "AC":
alternating voltage from the mains
transformer
"Bat +":
to the positive pole of a 12 V recharge-
able battery
"Bat -":
to the negative pole of the recharge-
able battery
2 Terminal strip TB1 for connection of up to four key-
pad controllers; to be connected to the contacts of
the same name of the terminal TB1 at the keypad
controller, also see chapter 4.4
3 Fuses:
F1 = quick-acting 1 A for the outputs "Strobe" and
"Bell" of the terminal strip TB3 (5) and for the output
"AUX 12V" of the terminal TB4 (6)
F2 = quick-acting 0.25 A for the keypad controllers
Only replace a blown fuse by one of the same type!
4 Holding clamps for the PCB (10)
5 Terminal strip TB3 for connecting an alarm unit
"Strobe":
to the strobelight; max. current rating
250 mA*
"Bell":
to the siren; max. current rating 500 mA*
"Bell SAB": anti-tamper loop for the alarm unit or
for an individual strobelight and siren
Note: For the power supply of an alarm unit a 12 V
rechargeable battery must be inserted which sup-
ports the internal power supply unit in case of alarm.
6 Terminal strip TB4
"PGM1":
programmable switching output (chap-
ter 5.4), max. rating 50 mA*
"SPKR":
connection for the supplied speaker or
another speaker (minimum impedance
16 Ω)
"AUX 12V": 12 V supply voltage for alarm sensors
or other additional units*
7 Mains voltage indication LED1
8 Volume control of the audio signal for the speaker
connected to terminal "SPKR" (6); however, alarm
tones are always reproduced at maximum volume
9 Terminal strip TB2
"TMP":
anti-tamper loop for all alarm sensors
connected
"AZ1...8":
connections of the alarm zones 1 to 8
Note: To be able to activate and deac-
tivate the alarm control system via a
key switch with pulsed contact (mo-
mentary pushbutton), connect it to the
contacts AZ5 and programme the zone
5 accordingly (chapter 5.1)
* The current load of all consumers connected must not exceed a
total of 1 A!