Puls+
When activating, the voltage goes from 0 V to 12 V
for approx. 3 seconds (already while the exit delay
time is running).
Bell
As long as the siren sounds, 12 V are present.
Strb.
As long as the strobelight is activated, 12 V are
present (even if the strobelight is only shortly
activated to confirm the activation).
EX/EN
12 V are present while the entry delay time or exit
delay time is running.
Walk
As long as the test mode (walk testing ...) is
activated, 12 V are present.
IntAl
In case of alarm triggering 12 V are present until
the alarm is reset via the keypad controller (also
when triggering a "panic" zone or "alert" zone).
Alarm
During an alarm triggering 12 V are present until
the alarm is reset (not when releasing a "panic"
zone or "alert" zone).
Panic
If a zone with the feature "Panic" has been activat-
ed, 12 V are present until the alarm is reset.
Puls–
When activating, the voltage goes from 12 V to 0 V
for approx. 3 seconds (already while the exit delay
time is running).
40) To confirm the selected setting, press the button
Yes. The display changes to:
Chan.1
Mode
F i r e
This menu item is not required for the DA-8000.
Please do not change the setting "Fire".
41) Press the button Yes. The display changes to:
Alarm
Restore
O f f
Also this menu item is not required for the DA-
8000. Please do not change the setting "Off".
42) Press the button Yes again. The display returns
e. g. to:
PGM
1 Mode
S W 1 2 V
To exit this menu level, press the button 0. The dis-
play shows:
Program .......
Output & Digi ?
5.5 Alarm reset authorization and alarm trig-
gering via the keypad controller
43) Starting from the operating step 42) of the pre-
vious chapter press the button No. The display
changes to:
Program .......
Reset & Keypad ?
44) Press the button Yes. The display shows:
Tamper
Reset
A n y
Here the alarm reset authorization while re-
cording a tampering action is programmed. The
default setting is that in case of tampering actions
the alarm is terminated by entering a desired
access code. For keeping this setting press the
button Yes.
For the option "Eng" (Engineer), press the but-
ton No once. The display shows:
Tamper
Reset
E n g
With this setting the acoustical signalizing can also
be terminated with any access code, however,
then the display shows:
!! SERVICE DUE !
This is to indicate that a technician has to repair
the damage caused by tampering first before the
alarm control system can be reactivated.
45) To confirm the setting, press the button Yes. The
display changes to:
Alarm
Reset
M a s t
Here the alarm reset authorization after an
alarm triggering is programmed. The default set-
ting is that the alarm can only be terminated by
entering a master code (default setting: 5, 6, 7, 8)
and by pressing the button Reset subsequently.
For keeping this setting press the button Yes.
To select another authorization, press the but-
ton No so many times until the corresponding indi-
cation is displayed:
Anti (anti code reset)
The alarm triggering can in fact be terminated by
entering a master code (default setting: 5, 6, 7, 8).
However, the alarm cannot be reset with the but-
ton Reset so that the alarm control system cannot
be reactivated. For this purpose a special software
and a PC are required.
GB
33