P1 Aud.
The signal will only sound in the activation mode
"Part 1" and "Part 3" during the exit delay time.
P2 Aud.
The signal will only sound in the activation mode
"Part 2" during the exit delay time.
The acoustical signalizing is made via the buzzers
of the keypad controllers and via the speaker.
25) To confirm the selected mode, press the button
Yes. The display changes to:
Confirm Mode
O f f
Press the button No so many times until the de-
sired visual confirmation of the activation is
displayed:
Off
There is no visual signalizing if the alarm control
system is activated.
Any
As soon as the alarm control system is activated
(both in the mode "Full" and in one of the modes
"Part ...") the connected strobelight will be activat-
ed for some seconds.
Full
Only after the alarm control system is activated in
the mode "Full", the strobelight will be activated for
some seconds.
26) To confirm the selected mode, press the button
Yes. the display changes to:
Quick Set
O n
With this adjustment the alarm control system can
also be activated with the button Quick at one
keypad controller even without entering a user
code. For keeping this adjustment press the but-
ton Yes.
To deactivate this activation facility, press the
button No. The display shows:
Quick Set
O f f
27) To confirm the selected adjustment, press the but-
ton Yes. The display changes to:
Entry
1 Time
3 0
Here the entry delay time is programmed which is
composed of two partial times. This delay time is
available to the operators when crossing an "E/E"
zone to deactivate the zone without triggering
alarm. While the first partial time is running (Entry
1 Time, default setting 30 seconds), the buzzers of
the keypad controllers and the speaker signalize a
pulsating tone. Then the second partial time starts
(Entry 2 Time, default setting 10 seconds). An
audio signal of a different sound now warns that
the end of the entry delay time is coming near. The
alarm control system must be deactivated before,
otherwise an alarm will be triggered.
For keeping the default setting for the first par-
tial time (30 seconds) press the button Yes. Other-
wise press the button No and enter the desired
time with the numerical keys with two digits.
28) To confirm the first partial time, press the button
Yes. The display changes to:
Entry
2 Time
1 0
Proceed the same way with the second partial
time.
29) To confirm the second partial time, press the but-
ton Yes. The display returns to:
F-Exit
Time
3 0
Die Taste 0 drücken. Das Display zeigt:
Program .......
Exit/Entry ?
5.3 Settings for the alarm triggering and the
panic button
30) Starting from operating step 29) of the previous
chapter press the button No. The display shows:
Program .......
Bell & Panic ?
31) Press the button Yes. The display shows:
Ring
Time
2 0
The time for the acoustical alarm is preset to
20 minutes. However, the strobelight is activated
until the alarm control system is deactivated again.
Important!
If it siren is installed outdoors, the siren time must
be limited in some countries (in Germany to
3 minutes as a maximum). Longer alarm times
may be reported to the police because of a dis-
turbing noise.
To programme another time, press the button No.
The display changes to:
Ring
Time
0 0< —
Enter the siren time in minutes with the numerical
keys.
Ring
Time
0 3< —
32) To confirm the selected setting, press the button
Yes. The display changes to:
Bell
Delay
0 0
There is no default setting of the response delay
time for the visual and acoustical alarm trig-
gering. For keeping this setting press the button
Yes.
GB
31