Part 2
Corresponds to the feature "Part 1", however, in the
mode "Part 2", zones with the mode "Part 2" or "Part 3"
are excluded from alarm triggering.
Part 3
If the alarm control system is partially activated in
mode "Part 3", a recording in the zones with the mode
"Part 1", "Part 2", or "Part 3" does not trigger an alarm.
Chime
If the alarm control system is deactivated and an alarm
is recorded in this zone, the buzzers in the keypad con-
trollers and the speaker are able to emit four short
audio signals. This function can be switched on and off
for all "Chime" zones together via the keypad control-
ler (see operating instructions).
With the alarm control system activated and an
alarm recording in a "Chime" zone always all signal
devices are normally activated.
Ch/P1
If the alarm control system is deactivated and an alarm
has been recorded in this zone, the buzzers in the key-
pad controllers and the speaker can emit four short beep
tones (also see mode "Chime"). With the alarm control
system activated in mode "Part 1" or "Part 3" and an
alarm recording in this zone no alarm will be activated.
Ch/P2
Same as Ch/P1, however, with the alarm control
system activated there will be no alarm triggering in the
mode "Part 2" or "Part 3".
Ch/P3
Same as Ch/P1, however, with the alarm control
system activated there will be no alarm triggering in the
mode "Part 1", "Part 2", or "Part 3".
Full
With the alarm control system activated and an alarm
recording in this zone all signal devices are normally
activated (standard setting without extra function).
– Operating steps –
1) After applying the voltage of the rechargeable bat-
tery or mains voltage, the display of the keypad
controller shows:
01 Jan 00:00
<<<
UNSET
The alarm control system is not activated. To
switch to the programming mode, enter the 4-digit
programming code (default setting: 1, 2, 3, 4) with
the numerical keys. Each pressing of the buttons
is confirmed by a short beep tone. After entering
the programming code, another audio signal
sounds and the display shows:
Do You Want to..
Set Engineer ?
2) Press the button No within 15 seconds, otherwise
the programming mode will be exited. The display
shows:
Do You Want to..
Test ?
>>>
3) Press again the button No. The display shows:
Do You Want to..
Delete Zone ?
4) Press the button No once more. The display
shows:
Do You Want to..
Select Options ?
5) Press the button Yes. The display shows:
Do You Want to..
Program Chime ?
6) Press the button No. The display shows:
Do You Want to..
Program Codes ?
7) Press the button No again. The display shows:
Do You Want to..
Set Date/Time ?
8) Press the button No once more. The display
shows:
Do You Want to..
View Log ?
9) Press the button No. The display shows:
Program ........
Zones ?
10) Press the button Yes. The display shows:
Select
11) Enter the number of the zone to be set, e. g.
button "1" for zone 1. The display shows:
Zone
1 Type
E / E
12) Press the button No so many times until the re-
quired type of the alarm response (type) is shown:
12 Hr, E/E, Access, Panic, 24 Hr, Fire, Alert, ET,
Pt E/E, or Key.
If the zone is to trigger alarm e. g. also with deac-
tivated alarm control system:
Zone
1 Type
2 4 H r
13) To confirm press the button Yes. The display
shows e. g.:
Zone
1 Mode
C h i m e
14) Press the button No so many times until the re-
quired mode is shown:
Part 1, Part 2, Part 3, Chime, CH/P1, CH/P2,
CH/P3, Full
For activating this zone both in the full activation
mode and partial activation mode:
Zone
1 Mode
F u l l
1..8
GB