7. Possible Malfunctions

In case of a disturbance disconnect the device from the power supply and close the
water supply. Before contacting customer service, check the possible malfunctions of
the device in the table below.
Problem
The device does
not turn on.
If the device does not turn on after trying some of the above solutions,
contact customer service.
The ventilator stops
working while the
device is in use
If the problem occurs again, contact customer service.
Internal lighting does
not work.
If the problem occurs again, contact customer service.
Water does not
reach the hose.
If the problem occurs again, contact customer service.
• Check the power supply
• Check if the device's fuses are damaged.
• Check if the device's door is closed properly.
• Check if the cooking / baking parameters are properly set.
• Check if the device does not display any error messages.
• Turn the device off and wait until the motor overheating
safety device turns itself on again.
• Check if ventilation ducts are blocked.
Use only temperature-resistant light bulbs!
Change the light bulb as follows:
• Check if the multipolar switch is open and the device
has cooled.
• Open the internal glass panel (6 „Cleaning and
maintenance").
• Remove the protective glass cover.
• Change the light bulb.
• Check if the water flow stopcock is open.
Possible solution