Drive Configuration
Minimum Frequency: In surface pump applications, placing DIP SW3 Position 6 in the OFF (down)
position will set the minimum output frequency to 30Hz (default). Move the switch to the ON (up)
position to set the minimum output frequency to 15Hz.
More precise settings are available when using the FE Connect mobile app. Refer to
Motor Settings" on page
Pressure Input Selection (DIP SW1 – Position 5)
Ensure that the drive is configured for the type of pressure transducer or sensor being used:
If using a 4-20 mA 100 PSI pressure transducer (included), DIP SW1 Position 5 must be in
the XDCR (down) position.
If using a standard pressure sensor, DIP SW1 Position 5 must be in the PS (up) position.
Adjusting Pressure Setting
Pressure Transducer: When using the 100 PSI pressure transducer, the desired
system pressure is set by using the pressure setpoint adjustment knob. The knob is
factory set to 50 PSI and is adjustable from 5 to 95 PSI in 5 PSI increments. Refer to
the indicator lines surrounding the switch and the corresponding legend printed on
the shield when setting the desired pressure setpoint.
The pressure setpoint must be adjusted with the drive powered OFF. When the drive
is powered ON, the screen will display the active system pressure.
NOTE: This knob is only compatible with the default 4-20 mA 100 PSI pressure
transducer. If using a pressure transducer with a different range, the FE Connect DIP switch (DIP
Switch 1 – Position 1) must be in the ON (up) position and the Pressure Transducer Type, Pressure
Transducer Range, and Pressure Setpoint parameters must be configured using the FE Connect
mobile app. Refer to
"Pressure Control" on page
Pressure Sensor: The sensor (1) is preset at the factory to 50 psi (3.4 bar), but can be
adjusted by the installer using the following procedure:
Remove the rubber end-cap.
Using a 7/32" Allen-wrench (2), turn the adjusting screw clockwise to increase
pressure and counter-clockwise to decrease pressure. The adjustment range is
between 25 and 80 psi (1.7 and 5.5 bar). Note: 1/4 turn = approximately 3 psi
(0.2 bar).
Replace the rubber end cap.
Cover the pressure sensor terminals with the rubber boot provided. Do not place
boot in direct sunlight.
IMPORTANT: Do not exceed the mechanical stop on the pressure sensor.
When the drive is powered ON, the display will show motor speed rather than the active system
pressure.