MAINTENANCE
Troubleshooting
Condition
Display
Run On
Green
Won't stop pump
Motor Frequency
Runs But Trips
Flashing Red
Green
Low Pressure
Motor Frequency
Green
High Pressure
Motor Frequency
Green
Audible Noise
Motor Frequency
No Display
FE Connect Light
On Solid
Cannot Connect to
Drive Wi-Fi
FE Connect Light
RFI-EMI
Green
Interference
Motor Frequency
System Regulates
Green
but displays 199P
48
Possible Cause
• Pressure sensor
placement and setting
• Tank pre-charge
pressure
• Impeller damage
• Leaky system
• Sized improperly (pump
can't build enough
head)
• Check fault code and
see corrective action
• Pressure sensor setting,
pump rotation, pump
sizing
• High temperature
• Pressure sensor setting
• Shorted sensor wire
• Fan, hydraulic, plumbing
• Display board cable
None
disconnected or loose
• Attempting to connect
to incorrect drive
• Out of Wi-Fi range of
drive
• Wi-Fi timeout expired
Off
• Poor grounding
• Wire routing
• The pressure in the
system is 199 psi or
199P
higher
Corrective Action
• Check frequency at low flows, pressure setting may be
too close to pump max head
• Verify precharge at 70% if tank size is larger than
minimum, increase precharge (up to 85%)
• Verify that the system will build and hold pressure
• Enable bump and/or aggressive bump
• Increase minimum frequency
• Proceed to fault code description and remedy
• Adjust pressure sensor, check pump rotation
• Check frequency at max flow, check max pressure
• High ambient and/or drive temperature will cause drive
to foldback power and run with reduced performance
• Adjust pressure sensor
• Remove sensor wire at Pressure Input Board, if drive
stops running, wire may be shorted
• Remove sensor wire at Pressure Input Board, if drive
continues to run, replace Pressure Input Board
• Remove sensor wire at new Pressure Input Board, if drive
continues to run, replace drive
• Verify condition of sensor wire and repair or replace if
necessary
• For excessive fan noise, replace fan
• If fan noise is normal, drive will need to be relocated to a
more remote area
• If hydraulic, try raising or lowering depth of pump
• Pressure tank location should be at entrance of water line
into house
• Verify cable connection between main control board and
display board
• Ensure the Wi-Fi SSID (hotspot name) you are
connecting to matches the drive you wish to connect to
• Wi-Fi range is 100 feet line-of-site, must be closer to
drive if walls or floors are between you and the drive
• Wi-Fi module not responding, cycle power to drive
• Cycle Wi-Fi radio on mobile device, refresh Wi-Fi
connection list
• If more than fifteen (15) minutes since last power cycle,
cycle power to drive
• If more than one (1) hour since last disconnection from
Wi-Fi, cycle power to drive
• Adhere to grounding and wire routing recommendations
• An additional external filter may be needed.
• The max pressure the display can show is 199psi. Use the
pressure gauge or Wi-Fi / FE-Connect app to view the
system pressure.