Accessories - Franklin Electric SubDrive 15 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour SubDrive 15:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS

Accessories

Accessories
Accessory
Air Screen Kit
Air Screen Kit
Air Screen Kit
Pressure Transducer
Transducer Cable Kit
Duplex Alternator Cable Kit
Enhanced Pressure Input
Board Replacement Kit
Enhanced Display Board
Replacement Kit
Filter (Input)
Filter (Output)
Filter (Surge Capacitors)
AMR Input Filter
IGF Input Filter
Lightning Arrestor
Moisture Sensor Kit
NEMA 3R Fan Replacement Kit
Pressure Sensor 25-80 PSI
Pressure Sensor (High: 75-150
psi, NSF 61 rated)
Sensor Cable Kit - Outdoor
Sensor Cable Kit - Direct Burial
Tank Drawdown Kit
54
Detail
Assists in preventing insects from entering and
damaging the internal components of the drive
Assists in preventing insects from entering and
damaging the internal components of the drive
Assists in preventing insects from entering and
damaging the internal components of the drive
4-20mA pressure transducer with 10 ft cable
Outdoor rated cable to connect transducer to drive
Communication cable kit required to use the built-in
Duplex Alternator function
Replacement board for drives that have experi-
enced a surge on the input board
Replacement board for drives with a damaged dis-
play
Filter used on the input side of drive to help elimi-
nate interference
Filter used on the output side of the drive to help
eliminate interference
Capacitor used on the service panel to help elimi-
nate power interference
Remedies electrical noise that can affect automated
meter readers used by utility companies
Reduces electrical noise from ground currents in soil
with high conductivity
Single-phase (Input power)
External sensor device that stops the drive when
water is detected
Replacement Fan
Adjusts pressure from 25-80 psi (2-lead cable)
Adjusts pressure from 75–150 psi (2-lead cable)
100 ft of 22 AWG cable (2-lead cable)
Designed to be run in a trench underground without
the use of conduit to surround it (4-leaded cable)
Enables Drawdown feature when using a pressure
sensor rather than a transducer
Options
All SD/MD Connect models
Date code 18B and newer
SD 50
Date code 18A and older
SD 15, SD 20, SD 30, MD, MDXT
Date code 18A and older
100 PSI
150 PSI
200 PSI
10 ft
25 ft
50 ft
100 ft
150 ft
200 ft
10 ft
50 ft
100 ft
All SD/MD Connect models
All SD/MD Connect models
All Models
All Models
All Models
SD 15, SD 20, MD Connect
All Models
Single-phase (Input power
All SD/MD Connect models
SD 15 and MD Connect models
SD 20, SD 30, MDXT models
SD 50 Connect models
All SD/MD Connect models
All SD/MD Connect models
All SD/MD Connect models
10 ft (3 m)
30 ft (9 m)
100 ft (30.5 m)
All models
Part
Number
575214902
226550902
226550901
226905902
226905903
226905904
226910901
226910902
226910903
226910904
226910905
226910906
226895901
226895902
226895903
226540902
226540912
225198901
225300901
225199901
226030901
226035901
150814902
226770901
226545904
226545905
226545903
226941901
225970901
223995902
225800901
225800902
225800903
225770901

Publicité