5.3 Countersunk mounting
After all electrical connections have been made,
the control unit can be inserted into the wall cut-out.
Use the short screws contained in the scope of supply to this end.
When inserting the screws, ensure no
damage is caused to any cables installed in
the wall. This can cause serious injury to
people and serious damage to property.
7
Changing of heating time limitation
The heating time limitation of the control unit is limited to 99min at the factory. This can be extended to up to
24 hours by setting the jumpers described below. The jumper set is available as an accessory under the order
number O-JUMP.
Tip: it is only possible to set the heating time to the precise minute at a limitation of 99min. From 99
min to 9.9 hrs, the limitation can be exactly set to 0.1h (6min). Beyond this, only in 1 hour steps.
Tip: the heating time limitation may be extended to a maximum of 6 hours for domestic use. For
heating time limitations >6 hrs, the relevant regulations of EN60335-2-53 must absolutely be heeded.
Running time Jumpers set
99min
6hrs
12hrs
24hrs
WE DO IT FIRST.
Instructions for installation and use – only for experts
Fig. 8 – Countersunk mounting
None
JP1
JP2
JP1 + JP2
L
N
U
Fig. 9 - Jumper heating time limitation and remote start
P. 8/14
N
U
N
JP3
JP1
JP2