11
Description of functions and operating elements
11.1 On/off button 1
The control unit can be switched on and off (stand-by) with this button. If the running time and temperature have
already been set, the control unit immediately starts to work with the last activated settings. The settings are
saved on switchover into stand-by.
11.2 Light button 2
The cabin light can be switched on at any time with this button. Even when the control unit is in stand-by mode.
The cabin light remains switched on, even after the end of the running time.
11.3 + button 3
Increases the value of the selected option. If the button is held down, the value increases more quickly. As soon
as the button is pressed, the display starts to fl ash and the target value is displayed.
11.4 Mode/OK button 4
This button enables you to switch between the temperature and running time display. The current actual value is
displayed.
Furthermore, this button serves to confi rm the target value.
11.5 - button 5
Reduces the value of the selected option. If the button is held down, the value increases more quickly. As soon
as the button is pressed, the display starts to fl ash and the target value is displayed.
11.6 Temperature and running time indicator 6
If the display lights up continuously, the respective actual value is displayed. The target value is depicted if one
of the buttons, 3 or 5, is pressed. The display fl ashes until the button 4 is pressed or the setting is auto-
matically adopted after xx seconds. The display then lights up continuously again and the actual value is
displayed again.
11.7 Selection of temperature heating circuit 1 7
The desired temperature can be set here. The setting is made with the 3 and 5 buttons. As long as the target
temperature is displayed, the indicator fl ashes 6. You can now confi rm the set value with 4 or wait until the
value is automatically adopted after 5 seconds.
Minimum value: 30°C
Maximum value: 70°C with radiator operation, 50°C with fi lm operation.
11.8 Selection of temperature heating circuit 2 8
The desired running time can be set here. The setting is made with the 3 and 5 buttons. As long as the target
temperature is displayed, the indicator fl ashes 6. You can now confi rm the set value with 4 or wait until the va-
lue is automatically adopted after 5 seconds.
Minimum value: 30°C
Maximum value: 70°C with radiator operation, 50°C with fi lm operation.
Tip: Sequence when scrolling through the individual options with the 4 button:
Temperature heating circuit 1 + 2
Temperature heating circuit 1
Temperature heating circuit 2
Running time
Fan
WE DO IT FIRST.
Instructions for use for the user
P. 11/14
EN