Installation instructions, only for experts
4. Settings
Baud rate:
57600
Data bits:
8
Stop bits:
1
Parity:
No
5. Overview of commands
5.1. General information
● Structure of commands (CMDs)
– Status queries: get (parameter)
Response (ACK): (PARAMETER) (ON/OFF) ;
– Value queries: get (parameter) val
Response: (PARAMETER) (VALUE) (UNIT) ;
– Status settings: set (parameter) (on/off)
Response: (PARAMETER) (ON/OFF) ;
– Value settings: set (parameter) val (value)
Response: (PARAMETER) (VALUE) (UNIT) ;
● The CMDs are terminated with CR (carriage return).
● An LF (line feed) is not necessary.
● Each ACK is ended with ";".
● Value setting and value query ACKs feature a space before the final ";".
Status setting and status query ACKs feature the ";" directly after the ON or OFF.
5.2. Command list
Func
tion
CMD
Sauna
set
set
get
get
Commands (CMD)
Param
Status Value
eter
sauna
on/off
sauna
val
sauna
sauna
val
Switches the sauna heater on/off
30-110
Sets a selected value between 30
and 110 °C as the preset temperature
Queries the sauna status (on/off)
Queries the preset temperature
p. 6/12
Description