hr
7.
GREŠKE U RADU
KVAR
PUMPA JE STALA a) Vidi paragraf 5.4 "In-
PUMPA NE KRE-
ĆE / NEPRAVI-
LAN RAD
PUMPA RADI ALI
NEMA PROTOKA
PUMPA JE BUČ-
NA
8.
EC IZJAVA O SUKLADNOSTI
LOWARA SRL UNIPERSONALE, SA SJEDIŠTEM U ULICI VITTORIO LOMBARDI 14-36075 MON-
TECCHIO MAGGIORE - VICENZA - ITALIA, IZJAVLJUJE DA SU PROIZVODI:
CIRKULACIONA CRPKA (VIDI PRILJEPNICU NA PRVOJ STRANICI)
U SKLADU SA ODREDBAMA SLIJEDEĆIH EUROPSKIH DIREKTIVA
• MAŠINE 2006/42/EZ (PRIVITAK II: TEHNIČKI FASCIKL SE NALAZI NA RASPOLAGANJU U FIRMI
LOWARA SRL UNIPERSONALE)
• ELEKTROMAGNETSKA KOMPATIBILNOST 2004/108/EZ
• EKO-DIZAJN 2009/125/EZ, DIREKTIVA (EZ) Br. 641/2009, DIREKTIVA (EZ) Br. 622/2012:
EEI ≤ 0, .... (VIDI PRILJEPNICU NA PRVOJ STRANICI)
(privitak I: "referentni indeks za najučinkovitije cirkulacione crpke je IEE ≤ 0,20.")
I U SKLADU SA SLIJEDEĆIM TEHNIČKIM ODREDBAMA:
• EN 809, EN 60335-1, EN 60335-2-51, EN 62233
• EN 61000-6-1:2007, EN 61000-6-3:2007
• EN 16297-2
MONTECCHIO MAGGIORE, 21.12.2012.g.
AMEDEO VALENTE
(DIREKTOR ENGINEERING R&D)
rev.00
Lowara je registrirani zaštitni znak tvrtke Lowara srl Unipersonale, podružnica Xylem Inc.
100
MOGUĆI UZROCI
dikatori"
a) Prisutnost nečistoća
unutar pumpe
a) Prisutnost zraka u su-
stavu
b) Ventil je zatvoren
a) Prevelika brzina pum-
pe
b) Preniski statički tlak
c) Prisutnost zraka u su-
stavu
POPRAVAK
a) Resetirajte pokazatelj greške
b) Provjerite električno napajanje i osigurače
a) Vidi paragraf 6 "Održavanje"
a) Izvucite zrak iz pumpe i sustava
b) Otvorite ventil
a) Smanjite set point
b) Povisite usisni tlak
c) Izvucite zrak iz pumpe i sustava
« PRIJEVOD »