Red light
Red light flashes rap-
idly
Error signals
The red light on the back of the terminal box will
in case of an error, indicate the type of error de-
tected by the electronics. Approximately, every
minute the light will flash a number of times.
Number of
flashes
1
2
3
4
5
6
(Regardless of fault, the pump will try to main-
tain normal operation)
6.
MAINTENANCE
ATTENTION
nance or repair work, replace the O-ring
between the pump body and the delivery
pipe. When remounting the motor part,
make sure the O-ring is correctly inserted.
If the motor shaft is jammed following a long
period of inactivity or due to the build-up of im-
purities, it must be released. Fit a screwdriver
through the hole in the vent valve and into the
slot at the end of the shaft and turn.
N.B.: any work on the electrical components
inside the pump must be performed by Service
Department.
Error. (See Error Sig-
nals)
Remote
Start-Stop
has been disconnect-
ed. (see remote start-
stop)
Error
Electronics temp too
high
Motor temp too high
Over power
Over current
Speed Error
Voltage problem (under
or over)
If the motor part is sep-
arated from the pump
body
during
mainte-
en
13