Boiler And Ricloud Alarms - Riello RiCLOUD Notice Installateur Et Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation of the prismatic dome
clear LED button on the WiFi Box and
boiler RF receiver
WiFi Box
In case of a boiler alarm (available
with OTBus connection between the
WiFi Box and the boiler or the RF
receiver and the boiler or RiCLOUD and
the boiler, if provided for by the OTBus
protocol), the alarm can be reset by
pressing the prismatic dome clear LED
button (A) (for alarm A99, reset from
the boiler).
With an ON/OFF connection, the relay
can be activated or deactivated by
pressing the prismatic dome clear LED
button (A).
4.2
The alarm is shown in alternation
with the room temperature detected
by RiCLOUD on the display.
A
In case of a boiler alarm (available
with OTBus connection between the
WiFi Box and the boiler, if provided for
by the OTBus protocol), the alarm can
be reset by pressing the BACK/RESET
button
the boiler).
9
and the temporary boiler alarms may
be automatically reset once the fault
has been resolved.
90

Boiler and RiCLOUD alarms

(for alarm A99, reset from
RiCLOUD alarms (rIE, E82, E83)

Publicité

Table des Matières
loading

Table des Matières