Parameter
Description
01 t0
Minimum safety temperature. The value can
be set from 1°C to 5°C.
Default set to 3°C.
Should RiCLOUD room probe detect a
temperature below the parameter set, a
heating request is generated – only when
HEATING in operating modes SUMMER/
DOMESTIC HOT WATER and OFF – taking into
account the hysteresis set under the HOn and
HOFF parameters.
08 HHCH
Maximun local central heating temperature
setpoint (available with OTBus connection
between the WiFi Box and the boiler or the
RF receiver and the boiler or RiCLOUD and the
boiler, if provided for by the OTBus protocol).
The value can be set between 80°C and 40°C
(for high temperature heating) or from 45°C
to 20°C (for low temperature heating).
08 LLCH
Minimum heating setpoint temperature
(available with OTBus connection between
the WiFi Box and the boiler or the RF receiver
and the boiler or RiCLOUD and the boiler, if
provided for by the OTBus protocol).
The value can be set from 10°C to HHCH -1°C.
10 CLI
Thermoregulation curve with external probe
connected to the boiler or external web probe
via the APP (available with OTBus connection
between the WiFi Box and the boiler or the
RF receiver and the boiler or RiCLOUD and the
boiler, if provided for by the OTBus protocol).
Default set to 1.2°C.
The value can be set from 0.2°C to 3°C.
The parameter in question affects the
calculation of the heating delivery setpoint
temperature.
80