6.4 Cable management

The cables must be adequately fastened to
the structure to avoid causing the cables
to be accidentally unplugged.
You must use cables suited to the type of
installation you are using.
Nominal section of the cables used:
consult the technical data in the relevant
chapter (15 Technical data, page 33).
Insert the cables into the cable glands.
If the cable has a pre-assembled connector, replace
the gasket inside the cable gland with the one
supplied. Insert the Ethernet cable in the gasket as
illustrated in the figure (Fig. 12, page 21). Pass the
cable with connector RJ45 through the M20 cable
gland.
Fig. 12
MNVCEVO_2203_EN
M16
Power supply
Digital I/O
Fig. 13
Tighten the cable glands.
Pay attention to the fixing. Tightening
torque : 1.5Nm (±0.2Nm) for M16 cable
glands, 2Nm (±0.2Nm) for M20 cable
glands.
If a cable gland does not have a cable inserted, a
specific cap must be inserted for closure. Always
close the cable glands with the stated tightening
torque.
M20
M16
Ethernet
21