Illuminators; Environment; Certifications; Certifications - Railway Applications - Videotec ULISSE EVO UE Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 105

15.1.9 Illuminators

LED illuminator
Wavelength: 850nm, 940nm (only UEIxxx), white
light
UEIxxx
• Wide beam: 40° (horizontal), 16° (vertical)
• Spot beam: 14° (horizontal), 14° (vertical)
UEIxxxP
• Wide beam: 13° (horizontal), 13° (vertical)
• Spot beam: 13° (horizontal), 13° (vertical)
Wide beam activation: based on the scene
brightness, from alarm input or manually
Spot beam activation (can be activated only when
the wide beam is active): can be activated on preset,
based on the zoom factor or with the wide beam
Automatic and remote switching on
No calibration required for light beam alignment
with the camera
The illuminator does not slow down the PTZ
camera's rotation speed
Automatic recognition of the type of illuminator
installed

15.1.10 Environment

For indoors and outdoors installation
Operating temperature
• Continuous functioning: from -40°C (-40°F) up to
+65°C (149°F) (+50°C (122°F) for versions painted
black)
• Temperature test complies with NEMA-TS 2-2003
(R2008) par. 2.1.5.1, test profile fig. 2-1 (from -34°C
(-29.2°F) to +74°C (165.2°F)) (not valid for versions
with integrated video analysis, VIDEOTEC
ANALYTICS)
• De-icing function intervention: from -40°C (-40°F)
up to -10°C (14°F)
Wind resistance
• PTZ camera static: 230km/h (143mph) max.
• PTZ camera moving, at the maximum speed, with
LED illuminator: 230km/h (143mph) max.
Relative humidity: from 5% up to 95%
36

15.1.11 Certifications

Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN61000-6-4,
EN50130-4, EN55032 (Class A)
Outdoor installation (CE): EN60950-22, IEC60950-22
Photobiological safety (CE): EN62471, IEC62471
IP protection degree (EN60529): IP66, IP67, IP68
Vibration test: EN50130-5, EN60068-2-6
Salty fog resistance: EN50130-5, EN60068-2-52
IK protection degree: IK10 (except glass window)
UL certification (UL60950-1, CAN/CSA C22.2 No.
60950-1-07,UL62368-1 CAN/CSA C22.2 No. 62368-1-
14): cULus Listed
Electromagnetic compatibility (North America): FCC
part 15 (Class A), ICES-003 (Class A)
Level of protection Type (UL50E): 4X, 6P
EAC certification
Restriction of Hazardous Substances (RoHS),
Directive 2011/65/EU
Waste Electrical and Electronic Equipment (WEEE),
Directive 2012/19/EU
KC certification (UE21A000J, UE21F000J)
15.1.12 Certifications - Railway
applications
Compliance to railway application standard:
EN50121-4 (the product requires the filter accessory
SURGEPR)
15.1.13 Certifications - Marine
applications
Lloyd's Register Marine Type Approval certification
(the product requires the filter accessory FM1010 if
powered in 24Vac or 24Vdc):
• Test Specification Number 1 (ENV1, ENV2, ENV3,
ENV5)
Electromagnetic compatibility: EN60945
Salty fog resistance: EN60068-2-52
Tested at 70°C (158°F) for 16 hours in compliance
with EN60068-2-2
MNVCEVO_2203_EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ulisse evo thermal uetUlisse evo dual ued

Table des Matières