6.4 Connector board description
BOARD DESCRIPTION
Connector/Ter
Function
minal
J1
Power supply line
J3
Relay, alarms
J9
Serial line
FUS1
Fuse
FUS2
Fuse
P1
Reset push-button
RJ45
Ethernet
RST (Connector J9)
Reset terminal
Tab. 1
P1
RJ45
J3
Fig. 12
18
FUS2
J9
RST
FUS1
J1
6.5 Cable entry
The telemetry line is not required for
normal functioning of the device.
To prevent the spread of flames or explosions from
the unit to the conduit system or cable gland to the
external environment, use connection in conformity
with IEC/EN60079-14.
All cable glands shall be ATEX/IECEx certified, as
appropriate, in type of explosion protection "db" and/
or "tb", rated IP66, suitable for the conditions of use
and correctly installed.
When conduit is used, a suitable ATEX/IECEx certified
stopping box shall be used, as appropriate, in type
of explosion protection "db" and/or "tb", rated IP66,
suitable for the conditions of use and correctly
installed. The stopping box must be fitted within
50mm (1.97in) from the enclosure wall.
To carry out the cabling process, disconnect the
removable connectors from the board (J1, J3, J9,
6.4 Connector board description, page 18). Connect
all the electrical cables and insert the Ethernet
connector (RJ45).
MNVCMPXHD_1801_EN