6.9 Connecting the power supply

6.9.1 24Vac/24Vdc power supply

Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
When commencing installation make
sure that the specifications for the power
supply for the installation correspond with
those required by the device.
Do not power the product using auto-
transformers.
Check that the power supply socket and
cable are adequately dimensioned.
Nominal section of the cables used:
consult the technical data in the relevant
chapter (15 Technical data, page 33).
In the case of a direct current power
supply, the polarity of the voltage applied
to the power supply terminal is irrelevant.
To power the unit, use the power supply units
indicated in the technical data sheet of the product
on the website: www.videotec.com, or use a toroidal
transformer with nominal power of at least 200VA.
Connect the power supply cable to the relative
connector (J4, Fig. 19, page 24).
Connect the ground cable to the relevant terminal
(GND_INT, Fig. 19, page 24).
24
The power cables must be sized according to the
ratio between the supply current and the distance to
be covered.
If the product is powered by two sources of power
simultaneously (24V and PoE 90W), only the 24V line
will be used, disabling the PoE 90W power supply.
GND_INT
J4
Fig. 19
The removable connector is supplied in the kit.
Fig. 20